Change Language
Hermetically Sealed Oil Filled Transformer
Hermetically Sealed Oil Filled Transformer

Hermetically Sealed Oil Filled Transformer

MOQ : 1 Unit

Hermetically Sealed Oil Filled Transformer Specification

  • Capacity
  • Up to 2500 kVA
  • Operating Temperature
  • -25C to +50C
  • Low Voltage
  • 0.4 kV - 0.433 kV
  • Cooling Type
  • ONAN (Oil Natural Air Natural)
  • Rated Voltage
  • 11 kV / 22 kV / 33 kV
  • Dimension (L*W*H)
  • Variable (Depends on Rating and Design)
  • Voltage Booster Type
  • Tap Changer (Off Circuit or On-load as per Specification)
  • Load Loss
  • Compliant with IS 1180 and IEC Standards
  • Coil Material
  • Copper / Aluminium (as per requirement)
  • High Voltage
  • Up to 33 kV
  • Standard
  • IS 1180 Part 1, IEC 60076
  • Product Type
  • Hermetically Sealed Oil Filled Transformer
  • Material
  • Copper
  • Output
  • Product wise
  • Frequency (MHz)
  • 50 Hertz (HZ)
  • Efficiency
  • 99.9%
  • Phase
  • Three Phase
  • Usage
  • Power Distribution and Transmission
  • Coil Structure
  • Layer Wound / Cylindrical
  • Coil Number
  • Multiple (Based on capacity)
  • Power Scope
  • Up to 2500 kVA
  • Weight
  • Approx. 1500 - 3500 kg (Varies with rating)
  • Service Life Expectancy
  • 25 Years Under Standard Operating Conditions
  • Tank Construction
  • Hermetically sealed corrugated steel tank, prevents moisture ingress
  • Insulation Class
  • Class A/F (as per design)
  • Paint Finish
  • Epoxy Primer with Polyurethane Top Coat (anti-corrosive)
  • Noise Level
  • < 60 dB at 1 meter
  • Impulse Withstand Voltage
  • Up to 170 kVp (as per rating)
  • Altitude Suitability
  • Up to 1000m above sea level (standard atmospheric conditions)
  • Accessories
  • HV & LV Bushings, Earthing Terminals, Lifting Lugs, Oil Drain Valve
  • Type Test & Routine Test
  • Compliant with IS/IEC requirements, Factory Test Certificates Provided
  • Protection
  • Pressure Relief Device, Buchholz Relay (optional), Oil Level Indicator
  • Oil Type
  • Mineral Oil as per IS 335
 

Hermetically Sealed Oil Filled Transformer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 2-3 Months
 

About Hermetically Sealed Oil Filled Transformer

We have premium quality Hermetically Sealed Oil Filled Transformer which is highly in demand for its various attributes such as noiseless performance, Eco-friendly structure, high stability of insulation and more. In addition to this, it ensures safety running, easy installation, shock resistance, seamless finishing, longer service life as well as cost effectiveness and smooth functioning. Furthermore, Hermetically Sealed Oil Filled Transformer used in industries for various purposes as it is reliable and easy to operate.

From the name of the Hermetically Sealed Transformer, it reflects that it is designed with the sealed tank which is equipped with the fins that permit the expansion at different range of temperature. This kind of electrical device has no conservator, and has zero connect with the atmosphere, which does not allow the passage of oxygen in it. The dielectric insulating fluid placed inside the transformer tank avoid the slugging and oxidation of the fluid. This Hermetically Sealed Oil Filled Transformer are easily accessible and maintenance free in nature which find its applications in exposed outdoor environments, like dust laden atmosphere, moisture, salt etc. This range of sealed transformer immersed in synthetic coolants are suitable for applications in indoors with ventilation. In industrial sectors, such as chemical plants or oil and gas terminals where poor accessibility makes regular maintenance impracticable. Such, Hermetically Sealed Oil Filled Transformer can be accommodated by certain devices that could measure heat related volume variations whereas gas cushion is used to compensate the volume variation due to heat.


Superior Moisture Protection

Hermetically sealed corrugated steel tanks ensure complete prevention of moisture ingress. This construction enhances transformer longevity by protecting the insulation and core from humidity-related degradation, making it ideal for diverse environmental conditions.


Reliable Performance and Testing

Every transformer undergoes rigorous type and routine testing as per IS and IEC standards. Factory test certificates are provided, assuring clients of consistent quality and performance. The transformers are engineered to withstand impulse voltages up to 170 kVp, guaranteeing operational safety.


Optimized for Efficiency and Safety

Achieve 99.9% efficiency with mineral oil cooling (ONAN type), minimal load loss, and a noise level below 60 dB. Safety mechanisms such as a pressure relief device and optional Buchholz relay enable safe, uninterrupted operation, while epoxy and polyurethane coatings provide superior corrosion resistance.

FAQ's of Hermetically Sealed Oil Filled Transformer:


Q: How does the hermetically sealed design benefit the transformer's performance?

A: The hermetically sealed corrugated steel tank eliminates exposure to external moisture, thereby maintaining optimal insulation quality and protecting internal components from corrosion and oxidation. This design substantially extends the transformer's service life and reliability.

Q: What is the process for testing and certification of these transformers?

A: All transformers undergo type and routine tests in compliance with IS 1180 Part 1 and IEC 60076 standards. Factory test certificates are issued for each unit, ensuring adherence to quality and performance benchmarks before delivery.

Q: When should a pressure relief device or Buchholz relay be used?

A: A pressure relief device is standard and protects against rapid pressure build-up within the transformer. The Buchholz relay is optional and recommended in sites where high sensitivity to internal faults or gas accumulation is desirable for enhanced safety.

Q: Where can these transformers be installed?

A: They are suitable for power distribution and transmission in urban, industrial, and rural settings. With altitude suitability up to 1000 meters and a robust anti-corrosive finish, they perform reliably in diverse climatic and atmospheric conditions.

Q: What insulation and cooling technologies are utilized in these transformers?

A: The transformer utilizes Class A or F insulation (depending on design) and is cooled using Oil Natural Air Natural (ONAN) methods with IS 335-grade mineral oil, ensuring efficient thermal management and safety under continuous operation.

Q: How efficient are these transformers and what is their expected service life?

A: With an efficiency rating of 99.9% and compliance with IS and IEC load loss standards, these transformers are engineered for optimal performance. When operated under standard conditions, their expected service life is up to 25 years.

Q: What are the main accessories provided with these transformers for ease of operation and maintenance?

A: Key accessories include HV and LV bushings, earthing terminals, lifting lugs, an oil drain valve, oil level indicator, and provisions for tap changers and optional Buchholz relays, simplifying installation and ongoing maintenance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Transformer Category

High Power Transformers

High Power Transformers

Price 300000 INR / Unit

Minimum Order Quantity : 1 Unit

Frequency (MHz) : 50 Hertz (HZ)

Cooling Type : ONAN/ONAF/OWAN/OWAF (Oil/Natural/Forced Air/Water)

Phase : Three Phase

Electrical Power Transformer

Electrical Power Transformer

Price 300000 INR / Unit

Minimum Order Quantity : 1 Unit

Frequency (MHz) : 50 Hertz (HZ)

Cooling Type : ONAN (Oil Natural Air Natural)

Phase : Three Phase

Converter Duty Transformer

Converter Duty Transformer

Minimum Order Quantity : 1 Unit

Frequency (MHz) : 50 Hertz (HZ)

Cooling Type : Oil Natural Air natural (ONAN)

Phase : Three Phase

Solar Application Transformer

Solar Application Transformer

Minimum Order Quantity : 1 Unit

Frequency (MHz) : 50 Hertz (HZ)

Cooling Type : ONAN (Oil Natural Air Natural)

Phase : Three Phase



Back to top