Change Language
Converter Transformer
Converter Transformer

Converter Transformer

Price 200000 INR/ Unit

MOQ : 1 Unit

Converter Transformer Specification

  • Dimension (L*W*H)
  • Depends on capacity (example: 2500 x 1700 x 2000 mm)
  • High Voltage
  • 11 kV to 33 kV
  • Coil Material
  • Electrolytic copper
  • Low Voltage
  • 415 V / 690 V / Custom
  • Load Loss
  • As per IS/IEC Standards
  • Capacity
  • 500 kVA - 15000 kVA
  • Rated Voltage
  • Up to 33 kV
  • Standard
  • IS 2026, IEC 60076
  • Operating Temperature
  • -25C to +50C
  • Voltage Booster Type
  • Step-up / Step-down
  • Cooling Type
  • ONAN/OFAF
  • Product Type
  • Converter Transformer
  • Material
  • Copper
  • Output
  • Product wise
  • Frequency (MHz)
  • 50 Hertz (HZ)
  • Efficiency
  • 99.9%
  • Phase
  • Three Phase
  • Usage
  • For industrial power conversion and distribution applications
  • Coil Structure
  • Double wound, core type
  • Coil Number
  • Multiple
  • Power Scope
  • Up to 15 MVA
  • Weight
  • Varies by rating (typically 800kg - 5000kg)
  • Impedance
  • As per customer specifications (typically 5% - 10%)
  • Paint Type
  • Epoxy/polyurethane for corrosion resistance
  • Accessories
  • Conservator, breather, radiator, oil level indicator
  • Tapping Range
  • 5% to 15% on HV side
  • Winding Type
  • Layer or disc wound as per specification
  • Noise Level
  • Less than 65 dB
  • Service Life
  • Greater than 25 years under nominal conditions
  • Protection
  • OLTC/OLBP, Buchholz relay, temperature sensor
  • Terminal Type
  • Copper lugs/bus bars
  • Mounting
  • Floor mounted
  • Insulation Class
  • Class A or F
 

Converter Transformer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 2-3 Months
 

About Converter Transformer

In order to attain maximum satisfaction of respectable clients, we are engaged in manufacturing and exporting Converter Duty Transformer. Our offered transformers are duly checked by our expert professional using tested quality materials & components. Available in different specifications and models, these transformers are broadly used as a set up transformer from generator to line voltage. Apart from this, Converter Duty Transformer is provided to our clients within specified time frame.

Features of Converter Duty Transformer :

  • Variable speed drives (VSD)
  • Aluminium electrolysis
  • DC arc furnace
  • Graphitizing furnaces
  • Traction substations
  • Copper refining
  • Sturdy structure
  • Impeccable finish
  • Supreme quality




Superior Efficiency and Longevity

Engineered with premium electrolytic copper and stringent IS/IEC standards, our transformers deliver an impressive 99.9% efficiency and a service life exceeding 25 years. With precise winding types-layer or disc wound-and custom insulation classes, they ensure stability even in demanding industrial settings.


Safety and Protection Features

Safety is paramount with integrated OLTC/OLBP protection, Buchholz relay, and temperature sensors. Each unit comes with a robust enclosure finished in corrosion-resistant epoxy or polyurethane paint, safeguarding the transformer in harsh environments while ensuring reliable operation.


Customizable for Varied Applications

Whether you need a step-up or step-down unit, our converters accommodate numerous configurations, offering flexible tapping ranges, mounting types, and accessory options. Designed for compatibility with different voltages and frequencies, they cater precisely to your industrial power transformation needs.

FAQ's of Converter Transformer:


Q: How does the winding type impact transformer performance?

A: The choice between layer or disc wound configurations ensures efficient management of electrical stress and heat dissipation. This enhances reliability, particularly for industrial operations requiring stable and consistent power delivery.

Q: What is the process for customizing a transformer for specific requirements?

A: Customers can specify desired parameters such as tapping range, impedance, voltage, and capacity. Our engineering team then designs and manufactures the transformer in compliance with IS 2026 and IEC 60076 standards, ensuring tailored performance for any application.

Q: When should I use a converter transformer in my industrial setup?

A: These transformers are recommended when you need to adapt voltage levels for large-scale processes or secure stable power supply to sensitive equipment, especially in industries where high efficiency, corrosion resistance, and long service life are vital.

Q: Where can these transformers be installed?

A: Our converter transformers are floor mounted and suited for indoor installations in factories, substations, and other industrial facilities across diverse climates, operating effectively within -25C to +50C.

Q: What are the major benefits of this transformer over conventional models?

A: Key advantages include an extended service life (>25 years), excellent noise control (<65 dB), advanced protection systems, customizable configuration, and high efficiency. This ensures minimal power losses and excellent return on investment.

Q: How is the transformer protected against harsh environmental conditions?

A: Corrosion-resistant epoxy or polyurethane paint, OLTC/OLBP mechanisms, Buchholz relay, and included accessories like conservators and oil level indicators protect the transformer from moisture, dust, and temperature extremes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Converter Duty Transformer Category

Heavy Duty Converter Duty Transformer

Heavy Duty Converter Duty Transformer

Minimum Order Quantity : 1 Unit

High Voltage : 3300 V / 6600 V / 11000 V or as per demand

Output : Product wise

Usage : Suitable for industrial, commercial, and heavyduty electrical applications where voltage conversion and electrical isolation are required.

Material : Copper

Frequency (MHz) : 50 Hertz (HZ)

Industrial Converter Duty Transformer

Industrial Converter Duty Transformer

Minimum Order Quantity : 1 Unit

High Voltage : Up to 33 kV

Output : Product wise

Usage : Industrial Converter, Rectifier Systems, Power Electronics Applications

Material : Copper

Frequency (MHz) : 50 Hertz (HZ)

Heavy Converter Duty Transformer

Heavy Converter Duty Transformer

Minimum Order Quantity : 1 Unit

High Voltage : up to 33 KV

Output : Product wise

Usage : Power / Distribution / Furnace etc.

Material : Copper

Frequency (MHz) : 50 Hertz (HZ)



Back to top